Home>>News

CX2000 Test Report and Product Video

2020-12-22

Model number: X2000 Class D 2000Wattsx1CH
Features:
2000W rms Class-D amplifier.
1 ohm load stable.
Double Side PCB and SMD components.
Adjustable Input level, LPF, Subsonic, bass boost function, Q control.
Advanced short circuit, overload, over heat protection.
Advanced clip limit / thermal power limit function.
Easy bridgeable with same amplifier.
Optional remote controller.
3 Detailed specs:
3.1 Test Condition.ì
All the specs were tested with following condition unless noted.
1. Power supply: 14.4V DC power supply
2. Test signal: 80Hz sine wave.
3. Loads: Resistor dummy load.
4. Environment: 25 degree C, open air.
5. Relative humidity: 70%.
6. Instrument: Audio Precision SYS-2322A.

3.2 Output power performance

Following table is the RMS output power with THD+N(<22KHz) value at 5%, 3%, 2% and 1%.
    Power
THD+N
RMS power (1ohm) RMS power (2ohm) RMS power(4ohm)
5% 2000W 1350W 780W
3% 1920W 1300W 760W
2% 1900W 1260W 740W
1% 1800W 1160W 660W
Table 1Output Power with THD+N
Following chart shows the output power with THD+N curve at 4ohm loads, 2ohm loads and 1ohm loads.
Chart 1. RMS output power @4ohm with THD+N


Chart 2. RMS output power @2ohm with THD+N
Chart 3. RMS power @1ohm with THD+N

3.3 Frequency Response

1. -3dB frequency response: 13Hz~224Hz.
2. -1dB frequency response: 18Hz~175Hz.



3.4 LPF & Subsonic Filter features

  1. LPF adjustable from 35Hz~224Hz with 24dB/Oct slope.
  2. Subsonic Filter adjustable from 14Hz~60Hz with 24dB/Oct slope.



Chart 4.LPF response
Chart 5.Subsonic Filter response

3.5 Bass Boost Feature

Bass boost center frequency adjustable from 34Hz~90Hz, level adjustable from 0~13dB.


Chart 6.Bass boost frequency adjust(bass boost level set @ 12dB)

Chart 7.Bass boost level adjust (bass boost frequency set at 48Hz)

3.6 Bass boost Q control

Chart 9. Bass boost Q control (bass boost frequency set at 50 Hz)  

3.7 THD+N
THD+N=0.165% @ 375W output power with 4ohm load.
3.8 Input level
0.2V~5V
3.9 Signal and Noise Ratio
>75dB
3.10 Protect Function
1. Overload: 
 Protect less than 0.8 Ohm loads at full scale output power.
2. Short Circuit:
 Full rated power short circuit protect test:  passed.
 Full rated power long last short circuit test: 10 minutes passed.
3. Over temperature:
 Limit output power while inner temperature reach 75 degree C, protect while inner temperature reach 85 degree C.
4. Low voltage:
Protect while power supply voltage lower than 8.6V.
5. Over voltage:
Protect while power supply voltage over 15.6V.
6. Power limit / Clip limit.
Clip limit while THD+N≥1%.
Power limit while inner temperature over 75 degree C.
 
3.11 Idle current and Efficiency:
1. Idle current: 1.39A
2. Efficiency: 
Load 4 OHM 2 OHM 1 OHM
Efficiency (THD+N @ 1 % ) 89.6% 83.7% 76.0%
3.12 Bridge method
X2000 can be bridged with same amplifier through single RCA cable, no addition switch needed. All the adjustable functions on slave amplifier will follow master once be bridged.
3.13 Dimension
This amplifier’s size is at 228mmX393mmX53mm(W,L,H).